Nordson ProBlue Flex Product Manual page 69

Adhesive melter with bbconn controls
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

E 2020 Nordson Corporation
2. Install the male fitting on the air filter assembly into the female fitting on
the melter, and tighten. See figure on the left for the location.
See Figure 3-14.
3. Position the air filter vertically with the filter bowl in the downward
position.
To correctly position the air filter, do the following:
a. Remove the M5 screw from the regulator cover.
b. Loosen the bulkhead fitting and nut, and then remove the cover.
c. Align the air filter in the correct position, and tighten the bulkhead
fitting and nut.
d. Reinstall the regulator cover and retaining screw.
CAUTION! Rigidly support the plant air supply before connecting it to the air
filter.
4. Connect a regulated plant air supply to the air filter inlet. If required, use
1
1
the
/
NPTF-to-G
/
4
4
in the installation kit.
NOTE: The air filter inlet is threaded to receive a male G
BSPP male adapter fitting (P/N 1034145) provided
Installation
3-29
1
/
BSPP fitting.
4
Part 1128350_02