I/O Declarations For The 4 Channel Temperature Control Expansion Board - Nordson ProBlue Flex Product Manual

Adhesive melter with bbconn controls
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

Hose/Applicator Expansion Base
G-16
Connector
Terminals
X5, X2
1 to 5
X8
1
X3, X9
1, 2
1, 2, 3, 7,
8, 9
X6, X1
5, 6, 11, 12
Part 1128350_02
I/O Declarations for the 4 Channel Temperature Control
Expansion Board
Type
Rating
24VDC @
2000 mA,
3.3V serial
Nordnet
communication
Chassis
Chassis
Ground
Ground
Heater
240VAC @
Power
2000W
RTD Sensor
5V logic
240VAC @
1000W per
Heater
zone, 1200W
Output
per pair and
2000W for
base
X5 is used to supply 24VDC and serial communication to
the 4 channel temperature control board
X2 is used to supply 24VDC and serial communication to
the expansion 4 channel temperature control board.
Used to supply chassis ground to the 4 channel
temperature control board.
Used to supply heater power to the 4 channel temperature
control board and to the expansion 4 channel temperature
control board.
The RTD sensor inputs provide the heater control
feedback from hose and applicator.
240VAC provided to hose and applicator heaters.
Use
E 2020 Nordson Corporation

Advertisement

Table of Contents
loading

Table of Contents