Nordson ProBlue Flex Product Manual page 116

Adhesive melter with bbconn controls
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

Troubleshooting
6-14
Identifying Electrical Components
Item Number
Connection Points
X1
Input
X4
Input
X3
Output
X10
Input
X12
Output
X2
Input
X5
Input/Output
X6
Input/Output
X8
Input/Output
X7
Input/Output
Item Number
Base Board Indicators
DS1
LED (Green)
DS2
LED (Yellow)
DS3
LED (Green)
DS4
LED (Yellow)
DS5
LED (Yellow)
DS6
LED (Yellow)
Base Board Connection Points
X6,X2
Input/output
X4
Input
X5
Input/output
X3
Input/output
X1
Input
Core Board Indicators
DS1
LED
(Green/Yellow/Red)
Part 1128350_02
Table 6-4: 6-channel Power Module (INT + H/A 1 and 2) (contd)
Type
Chassis ground
AC power to Melt and Manifold heaters from power distribution board
Switched AC power to Melt and Manifold zone heaters
RTD input from melt and manifold zones
400/480V sub-base control signals
AC power to H/A 1 and 2 from power distribution board
AC power outputs to H/A 1 heaters and H/A 1 RTD inputs
AC power outputs to H/A 2 heaters and H/A 2 RTD inputs
NordNet downstream to other power modules
NordNet upstream to LVC
Table 6-5: 4-channel Power Module (H/A 3 and 4, 5 and 6)
Type
AC power available to hose and applicator heaters
Applicator 2 heater control signal
5VDC supply available
Hose 2 heater control signal
Applicator 1 heater control signal
Hose 1 heater control signal
Control signals between temperature core board and 4-channel base
board
AC power input to hose and applicator heaters
Hose and applicator 1 heater outputs and RTD inputs
Hose and applicator 2 heater outputs and RTD inputs
Chassis Ground
RTD status listed in order of priority:
No base power board detected at startup
else no communication to ADC
else 1+ open/shorted RTDs detected
else:
(contd)
Description
Description
= red solid,
= yellow blink,
= yellow blink,
= green blink
Continued on next page