System Status Chart - Nordson ProBlue Flex Product Manual

Adhesive melter with bbconn controls
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

Basic Melter Operation
4-12

System Status Chart

Part 1128350_02
The following system LEDs show at a glance the status of the system.
System State
LED
Run
Idle
Alert
Fault
Description
Color
No alert or fault condition exists.
S
All conditions have been met for
running production.
Green
The Master Heat and Pump
S
controls must be ON.
No alert or fault condition, waiting for
run condition to be met.
Master Heat is On (heating).
S
Master Heat is Off.
S
Temperature Ready, but other
S
Blue
master controls, such as Pump or
optional Fill master controls, are
still toggled Off.
Ready Delay is enabled and in
S
use.
Setback is enabled and/or in use.
S
An Alert condition exists, caused
S
by an issue with either the
system itself or a component.
Yellow
Although product is still being
S
produced, there may be issues
that require your attention.
A Fault condition exists, caused
S
by a failure with either the system
itself or a component.
The Master Heater and Pump
S
Red
controls are automatically
toggled Off.
Production is halted until the
S
Fault condition is resolved.
E 2020 Nordson Corporation