Troubleshoot the Fill System

Fill Time Limit

E 2020 Nordson Corporation
WARNING! Allow only qualified personnel to perform the following tasks.
Follow the safety instructions in this document and all other related
documentation.
This fill system troubleshooting section covers only the most common
problems you may encounter. If you cannot resolve the problem using the
information provided in this section, contact your Nordson representative for
technical assistance.
The Fill Time Limit or maximum fill time is a user-specified amount of time
that the fill system operates. When the fill system is operating, it activates for
no less than 2 seconds and no more than 10 seconds at a time, then it has a
20 second Off interval. The Fill Time Limit is the sum of all the On times that
occur between the time the system calls for adhesive and the time the Fill
Time Limit is reached.
If the level sensor is not satisfied by the end of the Fill Time Limit, the control
system generates a fault. When a fill fault occurs, the heaters remain On but
the control system disables the fill system.
For detailed for troubleshooting fill system problems refer to one of the
following manuals:
-
ProBlue Flex Adhesive Melter Using the OLED User Interface Manual
(P/N 1128351).
-
ProBlue Flex Adhesive Melter OEM User Interface Manual
(P/N 1129255).
NOTE: For dimensions, parts information, and wiring details, refer to Fulfill
System in Optional Accessories (Appendix E).
Troubleshooting
6-29
Part 1128350_02