Nordson ProBlue Flex Product Manual page 114

Adhesive melter with bbconn controls
Hide thumbs Also See for ProBlue Flex:
Table of Contents

Advertisement

Troubleshooting
6-12
Identifying Electrical Components
Item Number
X1
Input/Output
X2
Input/Output
X6
Input/Output
X5
Input/Output
TB1
Input
X8
Input/Output
X9
Input/Output
X10
Input/Output
X13
Input/Output
X14
Input/Output
X15
Input/Output
X16
Input/Output
X17
Input/Output
TB3
Output
TB2
Input/Output
X18, X20
Input
X21
Input
X19
Input
TB4
Input/Output
Part 1128350_02
(contd)
Table 6-3: Low Voltage Control Board (contd)
Type
CompactCom M40 interface
Local user interface
Control signals for pump pressure control
Stacking I/O expansion interface
24V power supply input to board
Wireless Ethernet Interface
NordNet bus #1
NordNet bus #2
USB A interface
Ethernet (public), reporting, Profinet, Ethernet-IP, OPC-UA
Ethernet (private), expanded I/O, remote basic user interface
Ethernet (private), remote touch screen user interface
Ethernet (private), pattern control, adhesive tracking system
24V supply
Basic I/O, 1 input and 1 output channel
Adhesive level sensor input
Lid position sensor input
Input signals for over-temperature thermostats and power switch
Control signals for fill enable input and fill output
Description
E 2020 Nordson Corporation

Advertisement

Table of Contents
loading

Table of Contents