Pressure
Pressure Settings
Pressure Mode
Runup
Part 1128351_02
Defining Pressure Runup Settings and Monitoring Alert
Settings
Use Pressure Runup to allow the system pressure to automatically adjust to
maintain the same adhesive output when the line speed changes. You can
optionally decide if you want to receive pressure alerts when the system
pressure, hydraulic or pneumatic exceeds the defined thresholds.
NOTES:
S
The melter will go into an Alert condition only if the pressure meets or
exceeds the high/low thresholds for more than 10 seconds.
S
You can change the pressure scaling from the System Settings |
Preferences. The default is pneumatic.
S
The Set Point is a read-only, calculated value.
S
Press
on the OLED panel to clear and reset any Alert, Fault, or
Stop condition.

Pressure Runup Output Settings

Enter the maximum/minimum pressure and line speed you want the system
to use for production.
1. Select Output Setting, press > and enter the following information:
S
Low Speed Pressure Setting:
Pressure
Default
PSI
20
BAR
1.38
kPa
138
S
Low Line Speed
Pressure
Default
Meter/
6.1
Minute
Feet/
20
Minute
Minimum
Maximum
0
90
0
6.21
0
621
Minimum
Maximum
0
298.7
0
980