B-6
Operating Parameters
Temperature Control
20
21
22
Part 1024496_06
Temperature Units
Description:
Sets the units for temperature display.
Value:
C (degrees Celsius) or F (degrees Fahrenheit)
Resolution:
1 degree
Default Value:
C
Format:
—
Use:
—
Over Temperature Delta
Description:
The number of degrees that the temperature of any component can
increase over its assigned set-point temperature before an over
temperature fault (F3) will occur.
Value:
5 _C (10 _F) to 60 _C (110 _F)
Resolution:
1_C
1_F
Default Value:
15 _C (25 _F)
Format:
—
Use:
—
Under Temperature Delta
Description:
The number of degrees that the temperature of any component can
decrease from its set-point temperature before an under temperature
fault (F2) occurs.
Value:
5 _C (10 _F) to 60 _C (110 _F)
Resolution:
1_C
1_F
Default Value:
25 _C (50 _F)
Format:
—
Use:
—
E 2014 Nordson Corporation