Mircom TX3 Series Installation Manual page 10

Table of Contents

Advertisement

The basic TX3 system consists of the TX3 Touch Screen and depending on the
application, may be integrated with a combination of Mircom Voice Access,
Card Access, and Elevator Restriction Units. All access systems may be
networked together using a peer-to-peer RS-485 network, an Ethernet TCP/IP
network, or a combination of a TCP/IP network with RS-485 subnetworks.
A maximum of 63 units are supported on an RS-485 network or subnetwork.
Valid network addresses range from 1 to 63. Units with a real time clock, such as
Touch Screens and Card Access Units, require the address node to be 1. If you are
using an Ethernet TCP/IP network or a combination of a TCP/IP network with
RS-485 subnetworks you can add many more than 63 devices to your system. For
more information, see section 1.1.3 below.
The TX3 system is capable of providing ADC or NSL type voice access control
from a single panel or from a networked system.
The access system can be configured as an autodialer controller (ADC) or as a no
subscriber line (NSL) system. Both system setups can be configured for multiple
entrances with independent doors and control devices such as electric door locks,
cameras, and garage doors.
1.1.1
ADC and NSL Capability
TX3 supports full ADC and NSL telephone connectivity from a single Touch
Screen panel or from a networked system. A single panel supports up to five
ADC and/or NSL telephone lines.
1.1.2
Elevator Restriction Units
The TX3-ER-8-A Elevator Restriction Unit limits building accessibility by
granting visitor access only to the destination floor.
1.1.3
Other Controllers
Mircom devices, such as the Touch Screen and the Lobby Control Unit, can be
networked with the TX3 system through a peer-to-peer RS-485 network, an
Ethernet TCP/IP network, or a combination of an Ethernet network with RS-485
subnetworks.
The TX3 Configurator software can connect to any of these network
configurations. How you connect to the network (that is, through TCP/IP, USB,
a modem, or the COM port) determines what devices you can configure on the
system. The different network configurations are explained in the rest of this
section.
Figure 1 shows a configuration with TX3 controllers connected on an RS-485
network. Each controller has to have a unique network address on the RS-485
network. Up to 63 unique network addresses can be assigned. If you connect to
10