3.22.1

Control register

The AD converter is controlled by the AD mode control registers (ADMOD0, ADMOD1,
ADMOD2, ADMOD3, ADMOD4 and ADMOD5). AD conversion results are stored in the six
registers of AD conversion result higher-order/lower-order registers ADREG0H/L to
ADREG5H/L. Top-priority conversion results are stored in ADREGSPH/L.
Figure 3.22.2 to Figure 3.22.11 show the registers available in the AD converter.
AD Mode Control Register 0 (Normal conversion control)
ADMOD0
bit Symbol
(12B8H)
Read/Write
Reset State
Normal AD
Function
conversion
end flag
0:During
conversion
sequence
or before
starting
1:Complete
conversion
sequence
7
6
5
EOS
BUSY
R
0
0
Normal AD
conversion
BUSY Flag
0:Stop
conversion
1:During
conversion
Figure 3.22.2 AD Conversion Registers
92CF30-518
4
3
I2AD
ADS
HTRGE
R/W
0
0
AD
Start Normal
Normal AD
conversion
AD
conversion
conversion
at Hard
when
IDLE2
0: Don't Care
ware trigger
mode
1:Start AD
0: Disable
0: Stop
conversion
1: Enable
1: Operate
Always read
as"0".
TMP92CF30
2
1
0
TSEL1
TSEL0
0
0
0
Select Hard ware trigger
00: INTTB00 interrupt
01: Reserved
10:
ADTRG
11: Reserved