AD Mode Control Register 2 (Top-priority conversion control)
HEOS
ADMOD2
bit Symbol
(12BAH)
Read/Write
Reset State
Top-priority
Function
AD
conversion
sequence
FLAG
0: During
conversion
sequence
or before
starting
1: Complete
conversion
sequence
AD Mode Control Register 3 (Top-priority conversion control)
ADMOD3
bit Symbol
(12BBH)
Read/Write
Reset State
Function
Always
write "0".
7
6
5
HBUSY
R
0
0
Top-priority
AD
conversion
BUSY Flag
0:Stop
conversion
1:During
conversion
7
6
5
HADCH2
HADCH1
R/W
0
0
0
Top-priority analog input channel
select
Analog input channel select
Figure 3.22.4 AD Conversion Registers
92CF30-520
4
3
HADS
HHTRGE
0
Start
Top-priority
Top-priority
AD
AD
conversion
conversion
at Hard
0: Don't Care
ware trigger
1: Start AD
0: Disable
conversion
1: Enable
Always read
as"0".
4
3
HADCH0
0
Analog input
channel when
High-priority
conversion
<HADCH2:0>
000
AN0
001
AN1
010
AN2
011
AN3(Note)
100
AN4
101
AN5
110
Reserved
111
Reserved
Note: When using PG3 pin as
TMP92CF30
2
1
0
HTSEL1
HTSEL0
R/W
0
0
0
Select Hard ware trigger
00: INTTB10 interrupt
01: Reserved
10:
ADTRG
2
11: I
S Sampling Counter
Output
2
1
0
R/W
0
Always
write "0".
, it cannot be set.
ADTRG