Nortel Meridian 1 Replacement Manual page 46

Hardware replacement
Table of Contents

Advertisement

Page 46 of 362
Replacing equipment
553-3001-520 Standard 16.00 April 2000
6
Return cards to their slots at the rear of the UEM. Reconnect all cables to
connectors.
7
Position the backplane access plate. Replace the screws.
8
Return cards to their slots at the front of the UEM. Reconnect all cables
to connectors.
9
Turn on power to the UEM power supply by setting the power supply
switch to ON (right):
10 Enable the shelf by entering
ENLS l s
If a second shelf is assigned to a loop, enable that shelf also by entering
ENLS l s
End the session in LD 32 by entering
****
11 Test the shelf by testing each loop with
LD 30
LOOP l s
If there is a problem, an NWS system message will be produced.
12 End the session in LD 30 by entering
****
13 Tag defective equipment with a description of the problem and package
it for return to a repair center.