Nortel Meridian 1 Replacement Manual page 254

Hardware replacement
Table of Contents

Advertisement

Page 254 of 362
553-3001-520 Standard 16.00 April 2000
Replacing equipment
Removing equipment
1
Disable the host (MSI, EMSI, FDI, or IOP) card.
a
For an MSI, EMSI, or FDI card, the associated CPU must be
inactive.
If you need to switch CPUs:
LD 35
SCPU
****
Software disable the MSI, EMSI, or FDI card:
LD 37
DIS MSI 0
b
For an IOP card, software disable the IOP card associated with the
active CPU:
LD 137
DIS IOP
2
Set the ENB/DIS switch to DIS on the host card.
For an MSI, EMSI, or FDI card, also disconnect the cable to the card.
3
Unhook the locking devices on the card; pull it out of the card cage.
4
Remove the screw that secures the data cartridge. Gently unplug the
cartridge from the connectors on the component side of the host card.
exit LD 35
this also disables the associated CMDU or
IOP/CMDU, or both CMDUs or IOP/CMDUs
if they are in sync