Hardware replacement
Table of Contents

Advertisement

Figure 15
Field wiring terminals in the NT7D67CB PDU
NT7D67CB
BLO CB0 CB1
11 Remove the PDU:
Note: When a system is shipped, a set of screws secures the leveling
bracket at the rear of the PDU to protect against vibration during transit.
If the shipping screws were not removed during initial installation, you
must remove them now to pull the PDU out of the pedestal. Pull the
blower unit all the way out of the pedestal so you can access the shipping
screws on the leveling bracket.
a
Loosen the three screws that secure the PDU.
b
Remove the two vertical screws located in the rear of the PDU that
hold the L-bracket to the lower pedestal.
c
Pull the PDU out of the pedestal, being careful to not chafe the
cables against the pedestal.
d
Disconnect the frame ground wire from the PDU at the frame ground
bolt inside the pedestal.
Replacing equipment
BAT
BAT
BATRTN
BATRTN
LRTN
0,1
2,3
0,1
2,3
Page 157 of 362
FLTR / PWR DIST
UNIT ASSY
CB2
CB3
553-5800
Hardware replacement

Advertisement

Table of Contents
loading