Nt8D19 Memory/Peripheral Signaling Card - Nortel Meridian 1 Replacement Manual

Hardware replacement
Table of Contents

Advertisement

Page 174 of 362

NT8D19 Memory/Peripheral Signaling Card

553-3001-520 Standard 16.00 April 2000
Replacing equipment
Installing equipment
1
Set the ENB/DIS switch to DIS on the replacement card.
2
Insert the replacement card into the vacated slot and hook the locking
devices.
3
Set the ENB/DIS switch to ENB on the replacement card.
4
Software enable the superloop:
ENLL 28
a
When the process is complete, you will receive a system response.
b
If there is a problem, an NPR system message is generated and the
red LED on the faceplate of the card lights.
c
If there is no problem, exit LD 32:
****
5
Tag defective equipment with a description of the problem and package
it for return to a repair center.
Use this procedure to replace a memory/peripheral signaling card.

Advertisement