Nortel Meridian 1 Replacement Manual page 150

Hardware replacement
Table of Contents

Advertisement

Page 150 of 362
553-3001-520 Standard 16.00 April 2000
Replacing equipment
4
Reseat the blower unit:
a
Lift the unit slightly and slide it into the pedestal glides. Set the
toggle switch to ON (right).
b
Tighten the screws on the front of the unit.
5
Insert the system monitor card into the PDU. Tighten the screws on the
card. Reconnect cables to the system monitor faceplate.
6
Set all five circuit breakers on the PDU to OFF (down). Reconnect the
source of DC power.
7
One at a time starting with the breaker for the blower unit, set the circuit
breakers on the PDU to ON (up). Make sure the green LED lights on the
power supply unit(s) in each module.
Note: On initial power up, the blower may rotate slower than expected.
As the sensor detects heat, the blower will rotate more rapidly.
8
Replace the pedestal grills in the front and rear.
9
Tag defective equipment with a description of the problem and package
it for return to a repair center.