553-3001-520 Standard 16.00 April 2000
Replacing an NT7D10 PDU with an NT7D67CB PDU
12 Move the NT7D10 PDU out of the work area.
Installing equipment
The NT7D67CB PDU is much heavier than the NT7D10 PDU.
Note: The conduit attachment plate provided in the NT7D0902 Rear
Mount Conduit Kit must be installed as a safety cover and to restrain
wiring to the terminal block.
1
Drill two .234-in. screw holes in the rear of the pedestal (see Figure 39).
The holes will be used to install the conduit attachment plate.
Figure 39
Dimensions for drilling holes on the pedestal
Drill .234 in.
diameter through
(two places)
2
Place the NT7D67CB PDU next to the pedestal.
Figure 40 shows the PDU (labeled FLTR/PWR DIST UNIT ASSY on
the equipment) and the NT7D10CA System Monitor/Power Supply
Assembly (labeled XSM/PWR SUPPLY ASSY on the equipment).
Note: The NT7D09CA Pedestal has a brace that supports a leveling
bracket on the rear of the PDU. There is no room for the leveling bracket
in the NT7D09AA Pedestal, so the bracket must be removed before the
PDU is installed.
WARNING
9.13 in.
.75 in.
1.0 in.
553-5489