Nortel Meridian 1 Replacement Manual page 242

Hardware replacement
Table of Contents

Advertisement

Page 242 of 362
553-3001-520 Standard 16.00 April 2000
Replacing equipment
Removing equipment
1
Software disable the memory card:
a
The associated CPU must be inactive. If you need to switch CPUs:
LD 35
SCPU
b
All memory cards on this CPU must be disabled before the defective
memory card is removed. For each memory card:
DIS x
All memory cards on this CPU must be software disabled to avoid the
possibility of a sysload.
2
Unhook the locking devices on the card; pull it out of the card cage.
Installing equipment
1
Insert the replacement card into the vacated slot and hook the locking
devices.
a
Test and enable memory cards:
b
Test the replacement card:
MEM x
c
When the process is complete, you will receive a system response.
d
Enable each disabled memory card:
ENL x
"x" is a two-digit number—the first digit is the
associated CPU interface card and the second is
the memory card number
CAUTION

Advertisement

Table of Contents
loading

Table of Contents