Nt8D56Aa, Nt8D56Ac, Nt8D57 Module Power Distribution Unit - Nortel Meridian 1 Replacement Manual

Hardware replacement
Table of Contents

Advertisement

NT8D56AA, NT8D56AC, NT8D57 Module
Power Distribution Unit
3
Reconnect the power cable from the pedestal to the module:
a
Attach the power plug at connector J1.
b
Replace the I/O safety panel.
c
Replace the rear cover on the module.
4
Position the replacement panel and replace the screws.
5
Plug the power cable into the external outlet.
6
Set the circuit breaker on the panel to ON (up).
7
Replace the pedestal grill.
8
Tag defective equipment with a description of the problem and package
it for return to a repair center.
Use this procedure to replace the following module power distribution units
(MPDUs):
NT8D56AA single-breaker MPDU for the NT8D29 CE Power
Supply AC
NT8D56AC single-breaker MPDU for the NT7D14 CE/PE Power
Supply AC
NT8D57 dual-breaker MPDU for the NT8D06 PE Power Supply AC and
NT8D21 Ringing Generator AC
Module covers are not hinged; do not let go of the cover. Lift the cover
away from the module and set it out of your work area.
Replacing equipment
WARNING
Page 197 of 362