553-3001-520 Standard 16.00 April 2000
Replacing equipment
3
Insert the replacement card into the vacated slot and hook the locking
devices. Both red LEDs should flash three times and remain lit if the card
is good.
4
Set the ENB/DIS switch to ENB on the replacement card.
5
Software enable the card:
ENLX loop
Note: You must enable the card with the command ENLX. Enabling the
loops with the command ENLL does not enable the card.
6
Test each loop on the card (when each test completes, enter ****):
a
Test TDS capability:
LD 34
TDS loop
b
Test Conference capability:
LD 38
CNFC loop
c
Test MFS capability:
LD 46
MFS loop
d
If there is a problem, a TDS, CNF, or MFS system message is
generated and the appropriate red LED lights on the card faceplate.
7
Tag defective equipment with a description of the problem and package
it for return to a repair center.
This prompt is available in LD 34, LD 38, and
LD 46. Use the appropriate loop number (see
Step 1 in "Removing equipment" on
page 171).
"loop" is an even loop number
"loop" is an odd loop number
"loop" is an even loop number