Replacing equipment
Note: When IPE cards are installed, the red LED on the faceplate
remains lit for 2 to 5 seconds as a self-test runs. If the self-test completes
successfully, the LED flashes three times and remains lit until the card is
configured and enabled in software, then the LED goes out. If the LED
does not follow the pattern described or operates in any other manner
(such as continually flashing or remaining weakly lit), replace the card.
3
Software enable the card:
ENLC l s c
a
When the process is complete, you will receive a system response.
b
Exit LD 32:
****
4
Test the card:
LD 30
SHLF l s
Note: This command tests every card on the designated shelf.
a
If there is a problem, an NPR system message is generated and the
red LED(s) on the faceplate of the card will remain lit.
b
If there is no problem, exit LD 30:
****
5
Tag defective equipment with a description of the problem and package
it for return to a repair center.