Nortel Meridian 1 Replacement Manual page 128

Hardware replacement
Table of Contents

Advertisement

Page 128 of 362
553-3001-520 Standard 16.00 April 2000
Replacing equipment
26 Software enable, from the active side, the clock controller and PRI/DTI
cards:
a
Enable the clock controller card:
LD 60
ENL CC x
TRCK aaa
b
Enable the PRI/DTI cards:
ENLL loop
****
27 Follow the appropriate steps below to reinstall and check the system
monitor:
a
If you replaced the card cage in the column with the master system
monitor:
Reconnect the RJ11 cable to J6, then the cable to J3. Reinstall the
system monitor.
b
If you replaced the card cage in the column with the slave system
monitor:
Reinstall the system monitor in column 1 first.
On the master system monitor, reconnect the RJ11 cable to J6, then
the cable to J3. Reinstall the system monitor.
c
Enter:
LD 37
STAT XSM
****
28 Tag defective equipment with a description of the problem and package
it for return to a repair center.
if necessary, set tracking
exit LD 60
check the status of the system monitors
exit LD 37