NT8D1103 CE/PE Module Card Cage

3
Reinsert the power supply and hook the locking devices.
4
Position the metal plate in front of the MPDU and install the mounting
screw in each corner.
5
Connect the power plugs to the rear of the MPDU.
6
Position the I/O safety panel. Tighten the screws.
7
Set the circuit breaker(s) on the replacement MPDU to ON (up).
8
Reset the main circuit breaker in the column pedestal to ON (up) and
replace the pedestal grill.
9
Tag defective equipment with a description of the problem and package
it for return to a repair center.
To replace a defective backplane in an NT8D11 CE/PE Module, you must
replace the card cage. Use this procedure to replace the CE/PE Module card
cage.
Module covers are not hinged; do not let go of the cover. Lift the cover
away from the module and set it out of your work area.
Removing equipment
1
Unseat disks in the Floppy Disk Unit (FDU) or Small Systems Multi
Disk Unit (SMDU) from the disk drives.
2
Turn off power to the column or the module power supply:
— With AC power, set the main circuit breaker for the column to OFF
(down) in the rear of the pedestal.
Due to hazardous voltage in AC-powered systems, power to the entire
column must be shut down. This shuts down all functions in the
column.
Replacing equipment
WARNING