Nortel Meridian 1 Replacement Manual page 139

Hardware replacement
Table of Contents

Advertisement

CNI s p g
****
LD 43
EDD
****
Insert the CNI card in the new slot. Move the cables to the shrouds on
the backplane to the connectors for the new slot.
Enable the CNI card and switch the CP cards:
a
Set the NORM/MAINT switch to NORM on the active CP card.
b
LD 135
ENL CNI c s
SCPU
****
Use the following procedure to replace a CNI card.
Removing equipment
1
The Core associated with the CNI card must be inactive:
a
If you need to switch Cores:
LD 135
SCPU
b
Set the NORM/MAINT switch to MAINT on the active CP card.
2
Set the ENB/DIS switch to DIS on the CNI card you are replacing.
3
Unhook the locking devices on the card; pull it out of the card cage.
Replacing equipment
add group(s) to new slot
exit LD 17
datadump the new configuration
exit LD 43
Page 139 of 362
Hardware replacement