Nortel Meridian 1 Replacement Manual page 133

Hardware replacement
Table of Contents

Advertisement

10 Enable the IOP and check its status:
LD 137
ENL IOP
STAT IOP
11 To update the ROM on the replacement IOP card to the software
currently residing on the CMDU hard disk:
Note: Refer to "Software installation tool reference" in Software
Conversion Procedures (553-2001-320).
a
Activate the software installation tool by inserting disk A1 from the
software package into the CMDU in the Core containing the
replacement IOP card.
b
Press the MAN RST button on the CP card in the Core containing
the replacement IOP card.
c
Select the following options in sequence:
<f>
<y>
d
Specify software installation from the hard disk and follow screen
directions until the install menu returns.
e
Remove the disk from the CMDU.
f
Select the following options to quit and reboot the system:
<q>
<y>
<a>
Replacing equipment
to load the program
to enable the IOP
to check the IOP status
to install IOP ROM only
to start installation
to quit
to confirm quit
to reboot the system
Page 133 of 362
Hardware replacement

Advertisement

Table of Contents
loading

Table of Contents