NT6D65 and NTRB34 Core to Network Interface Cards

553-3001-520 Standard 16.00 April 2000
Replacing equipment
Use this procedure to replace the Core to Network Interface (CNI) or Core to
Network Interface 3 (CNI-3) card. See the X11 Administration
(553-3001-311) for a description of all maintenance commands, and the X11
System Messages Guide (553-3001-411) for interpreting system messages.
Replacing the CNI card in a nonredundant system, such as 51C, will
disrupt system operation. If possible, schedule the replacement at the
lowest traffic time (after midnight).
Module covers are not hinged; do not let go of the cover. Lift the cover
away from the module and set it out of your work area.
Before replacing a CNI or CNI-3 card, you can test it in an unused CNI slot
(in case, for example, there is a bent pin on the backplane). If the card works
correctly in the new slot, you can leave it there. To switch slots:
The Core associated with the CNI card must be inactive:
— If you need to switch Cores:
LD 135
SCPU
— Set the NORM/MAINT switch to MAINT on the active CP card.
Software disable the CNI card:
DIS CNI c s
****
Software configure the new slot:
LD 17
EXT x 3PE
CNI X s p
WARNING
WARNING
"c" is the CPU (0 or 1), "s" is the card slot (8–12)
exit LD 135
"x" is the number (0–4) of the associated 3PE
card(s)
delete the group(s) associated slot