When "DATADUMP COMPLETE" and "DATABASE BACKUP
COMPLETE" appear on the terminal, enter
****
If the data dump is not successful, do not continue; contact your
technical support organization. A data dump problem must be
corrected before proceeding.
To access the Core during the replacement procedure, connect a terminal to
the J25 port on the I/O panel in the Core/Network Module. To communicate
with the processor, you must use the following settings on the terminal:
9600 baud, 7 data, space parity, 1 stop bit, full duplex, XOFF
Upgrading the IOP/CMDU or IOP and CMDU to an IODU/C
1
Insert the Database Transfer Utility diskette which corresponds to your
source (existing) Call Processor card into the IOP/CMDU or CMDU.
2
Press the MAN RST button on the CP card.