Replacing equipment
16 Remove the diskette from the IODU/C and select <q> to quit and reload
the system.
17 Select <y> to confirm quit
18 Select <a> to reboot the system.
The system will automatically perform a sysload and system
initialization during which several messages will appear on the system
terminal. Wait until initialization has finished (INI messages are no
longer displayed on the system terminal) before continuing.
19 In the inactive Core, enable the NT6D65 CNI cards by setting the
ENB/DIS faceplate switches to ENB.
20 In the inactive Core, perform the following steps in uninterrupted
sequence:
a
press and release the MAN RST button
b
when SYS700 messages appear on CP LCD display, set the
MAINT/NORM switch to NORM.
Within 60 seconds, the LCD will display the following messages,
confirming the process.
RUNNING ROM OS
ENTERING CP VOTE
An "HWI534" message from the CPSI or SDI port indicates the start of
memory synchronization. Within 10 minutes, an HWI533 message on the
inactive Core CPSI or SDI TTY indicates the memory synchronization is
taking place. Wait until the memory synchronization is complete.
21 Switch the NORM/MAINT switch on the active CP card to NORM.
22 Synchronize the disk drives:
LD 137
SYNC
****
Note: Synchronization may take up to 50 minutes.
to load the program
to synchronize the drives
to exit the program