QPC215 Segmented Bus Extender Card

553-3001-520 Standard 16.00 April 2000
Replacing equipment
Use this procedure to replace a segmented bus extender (SBE) card.
See the X11 Administration (553-3001-311) for a description of all
maintenance commands, and the X11 System Messages Guide
(553-3001-411) for interpreting system messages.
Module covers are not hinged; do not let go of the cover. Lift the cover
away from the module and set it out of your work area.
Removing equipment
1
Software disable the SBE (the QPC441 3-Port Extender Card will also
be disabled):
a
The CPU associated with the SBE must be inactive. To switch
CPUs:
LD 35
SCPU
b
Disable the SBE:
DIS EXT xxx
Table 12
Extender codes
Extender number
0G0
0G1
0G2
0G3
0G4
1G0
1G1
1G2
1G3
1G4
WARNING
Table 12 lists extender codes specified by "xxx"
From
CPU 0
CPU 0
CPU 0
CPU 0
CPU 0
CPU 1
CPU 1
CPU 1
CPU 1
CPU 1
To
Network Group 0
Network Group 1
Network Group 2
Network Group 3
Network Group 4
Network Group 0
Network Group 1
Network Group 2
Network Group 3
Network Group 4