Nortel Meridian 1 Replacement Manual page 245

Hardware replacement
Table of Contents

Advertisement

3
Connect cables to the replacement card; connect the bottom cable first.
4
Set the ENB/DIS switch to ENB on the replacement card.
5
Software enable any cards that were disabled:
a
To enable the CMA:
ENL CMA x
b
To enable each memory card:
ENL x
c
Set the NORM/MAINT switch to NORM on both interface cards.
6
Test the CMA:
TCPU
a
A CED065 message may be generated from this test. If this occurs,
enter TCPU again to clear this condition.
b
If the replacement CMA is faulty, further system messages will be
generated and the red LED will light on the faceplate of the card.
c
If there is no problem, exit LD 35:
****
7
Tag defective equipment with a description of the problem and package
it for return to a repair center.
Replacing equipment
Hardware replacement
Page 245 of 362