Hardware replacement
Table of Contents

Advertisement

Page 266 of 362
553-3001-520 Standard 16.00 April 2000
Replacing equipment
7
Check to see that all cards were enabled.
Check the status of the IGS card:
LD 39
STAT IGS x
If the card is still disabled, enable it:
ENL IGS xx
****
Check the status of SDI ports:
LD 37
STAT
If any port still disabled, enable it:
ENL TTY x
****
Check the status of the peripheral signaling card:
LD 32
STAT PER x
If the card is still disabled, enable it:
ENPS x
****
8
Tag defective equipment with a description of the problem and package
it for return to a repair center.
"x" is the IGS card number—0 to 19
exit LD 39
exit LD 37
Table 13 lists peripheral signaling card numbers
exit LD 32