Nortel Meridian 1 Replacement Manual page 210

Hardware replacement
Table of Contents

Advertisement

Page 210 of 362
Table 6
Option 81C NTND95AA cable connections to 3PE cards
Network
Cable label
group
0
CPU1-CNI-12A to 3PE-GRP0/1-J3
0
CPU1-CNI-12C to 3PE-GRP0/1-J4
1
CPU1-CNI-12D to 3PE-GRP1/1-J3
1
CPU1-CNI-12F to 3PE-GRP1/1-J4
2
CPU1-CNI-13A to 3PE-GRP2/1-J3
2
CPU1-CNI-13C to 3PE-GRP2/1-J4
3
CPU1-CNI-13D to 3PE-GRP3/1-J3
3
CPU1-CNI-13F to 3PE-GRP3/1-J4
4
CPU1-CNI-14A to 3PE-GRP4/1-J3
4
CPU1-CNI-14C to 3PE-GRP4/1-J4
553-3001-520 Standard 16.00 April 2000
Replacing equipment
2
Disable all network loops on the shelf by disabling the peripheral
signaling card:
LD 32
DSPS x
****
3
Disable all other cards that might be in the module, such as serial data
interface (SDI) cards or primary rate interface (PRI) cards.
If the system terminal is assigned to an SDI that will be disabled,
assign it to another port before the SDI is disabled.
Connector
housing
Group 0
Group 0
Groups 1 & 2
Groups 1 & 2
Groups 1 & 2
Groups 1 & 2
Groups 3 & 4
Groups 3 & 4
Groups 3 & 4
Groups 3 & 4
Table 8 lists the loops represented by "x"
exit LD 32
CAUTION
Connector
3PE
position
connector
H12
J3
H14
J4
H10
J3
H12
J4
H14
J3
H16
J4
H10
J3
H12
J4
H14
J3
H16
J4