Nortel Meridian 1 Replacement Manual page 140

Hardware replacement
Table of Contents

Advertisement

Page 140 of 362
553-3001-520 Standard 16.00 April 2000
Replacing equipment
Installing equipment
1
Set the ENB/DIS switch to DIS on the replacement card.
2
Insert the replacement card into the vacated slot and hook the locking
devices.
3
Set the ENB/DIS switch to ENB on the replacement card.
4
Set the NORM/MAINT switch to NORM on the active CP card.
5
Software enable and test the CNI card and configured ports on the card:
ENL CNI c s
TEST CNI c s
SCPU
****
Note: Due to the need to reestablish memory shadowing and contents,
the test command may take a minute or more depending on memory size.
The LED on the CNI card flashes as the test runs.
If there is a problem, a CCED system message is generated (LEDs on the
CNI cards stay lit on the inactive Core).
Note: If the network loop corresponding to a CNI port is not enabled, the
LED for that port may not go out.
6
Tag defective equipment with a description of the problem and package
it for return to a repair center.
"c" is the CPU (0 or 1), "s" is the card slot (8–12)
exit LD 135