Replacement procedure for Option 51C systems

553-3001-520 Standard 16.00 April 2000
Replacing equipment
7
Insert the database diskette into both IODU/Cs for backup. Load LD 43
and datadump. This creates a backup on the floppy disk in the active
IODU/C.
LD 43
EDD
Data dump complete (or database backup complete) is printed when
the data dump has been successfully completed. Investigate any EDD
messages. Refer to X11 Administration (553-3001-311).
8
Evaluate the number of call registers and telephone buffers that are
configured for the system. Refer to Capacity Engineering
(553-3001-149).
The card replacement procedure is complete.
To perform this procedure, the following is required:
an Install diskette specific to your CP type
a CD-ROM containing system software
Keycode diskette
Database diskette(s)
one NT5D61AA IODU/C card
one IODU/C Security Device
a Database Transfer Utility to archive the IOP/CMDU or CMDU
database on 2MB floppy diskettes.
Performing a data dump
Before starting this procedure, make a backup copy of the customer database
on a 4MB diskette using the data dump routine:
1
Log into the system
2
Load the Equipment Data Dump Program (LD 43). At the prompt, enter
LD 43
3
When "EDD000" appears on the terminal, enter
EDD
to load the program
to begin the data dump