Nt8D53Ca Power Distribution Unit Ac - Nortel Meridian 1 Replacement Manual

Hardware replacement
Table of Contents

Advertisement

Page 192 of 362

NT8D53CA Power Distribution Unit AC

553-3001-520 Standard 16.00 April 2000
Replacing equipment
Use this procedure to replace the power distribution unit (PDU) for
AC-powered systems.
Module covers are not hinged; do not let go of the cover. Lift the cover
away from the module and set it out of your work area.
Removing equipment
1
Turn off power at the distribution box. If the column is not hardwired,
unplug the power cable.
2
Remove the grill on the rear of the pedestal. Figure 30 shows the location
of the unit in the rear of the pedestal.
Figure 30

NT8D53CA Power Distribution Unit AC

Main circuit
breaker
3
Loosen the three mounting screws that secure the field wiring access
plate. Lift the plate over the screws and set it aside.
WARNING
System monitor
Mounting screw
Power distribution
Mounting screws
unit—AC
553-3013