Event
Category Parm1
0 - 7
N/A
8
1
9
0 to 5
10
0 to 8
11
0 or 1
12
1
13
1
14
1
15
1
16
0 to 1000000
17
0 to 250
18 - 20
N/A
21
0 or 1
22
0 or 1
23
0 or 1
24
0 or 1
25
0 or 1
26
0 or 1
Parm2
Description
N/A
Reserved
Modem power up indication
1
Modem GSM registration (see AT+CREG command description for GSM regis-
0 to 5
tration status information)
Modem GPRS registration (see AT%CGREG command description for GPRS
0 to 8
registration status information)
Receipt of IP address.
0 = No IP address
0 or 1
1 = Valid IP address obtained
1
Timer 1 (set by AT$EVTIM1)
1
Timer 2 (set by AT$EVTIM2)
1
Timer 3 (set by AT$EVTIM3)
1
Timer 4 (set by AT$EVTIM4)
GPS Distance (unit of measurement is: meters)
This input event has been replaced by the AT$ODOMETER (input category
1000000
70) or AT$TODOM (input Category 91) input events for more accurate data
on newer devices and scripts. The event remains valid for legacy applications.
250
Current Velocity (unit of measurement is: Knots)
N/A
Reserved
Geo Fence #1. See AT$GEOFNC command for details on setting a circular
geo-fence
0 or 1
0 = Leaving Geofence area
1 = Entering Geofence area
0 or 1
Geo Fence #2
0 or 1
Geo Fence #3
0 or 1
Geo Fence #4
0 or 1
Geo Fence #5
MT Power Save Event
0 or 1
0 = Exit Power Save Mode
1 = Enter Power Save Mode