AT$OBDBBT Backup Battery Timer

AT$OBDBBT
Command Function
Syntax Query
Syntax
Write Syntax
Write Response
Read Syntax
Read Response
Execute Syntax
Execute Response
Unsolicited Response
Parameter Values
<time>
<time_remaining>
Notes
Example
Backup Battery Timer
This command is used to configure the length of time that the unit will run on
internal battery power after main power is removed.
AT$OBDBBT=?
$OBDBBT: (30-6000)
AT$OBDBBT=<time>
OK
AT$OBDBBT?
$OBDBBT: <time>,<time_remaining>
N/A
N/A
N/A
Time (in seconds) to remain running after main power has been removed
Range: 30-6000
Default: 300
Time (in seconds) remaining before shutting down.
This value is calculated by subtracting the elapsed time since the loss of main
power from the run time specified by this command.