Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
C
Miscellaneous Procedures
Enable/Disable Embedded Messaging
Enable/Disable Embedded Messaging
Release 10 supports the capability to disable and enable the embedded Intuity
AUDIX messaging system. Configured from the administration web pages, a
disable/enable link allows the user to toggle between active/inactive on-board
messaging capability. When the embedded message is active, a 'disable
messaging' link is present. When the embedded messaging in inactive, the
'enable messaging' link is present, and all web page references to INTUITY
AUDIX messaging are removed. In the active messaging state, the appropriate
backup-restore pages display the various Intuity AUDIX backup options, whereas
in the inactive messaging state, the web pages are modified to not display the
message-related backup options.
Impact on Maintenance
When Intuity AUDIX is disabled on the system, the ports on the CWY1 board
become unavailable. As a result, maintenance is disabled for the CWY1 board. To
counteract this and enable maintenance for the CWY1 board, at least one port on
the board must be administered.
Perform the following steps to enable maintenance for the CWY1 board when
Intuity AUDIX is disabled:
1. Add a station using the next available extension:
(For example, if using the Avaya Site Administration tool, click on Add
station, and click Next.
2. Enter 1A1201 in the Port field.
3. Enter 2500 in the Type field.
4. Enter CWY1 Test Port in the Name field.
5. Submit the form.
6. Perform a test port 1A1201 command, and verify that the test passes.
Issue 6
December 2001
C-23