Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
1
Install and Cable the Cabinet
Set neon voltage to prevent ring ping
Set neon voltage to prevent ring ping
NOTE:
There is no need to set neon voltage on the Avaya IP600.
NOTE:
If the ringing option is set to 50 Hz, neon voltage is not available. If 25 Hz is selected,
the maximum voltage is 120 volts. See
page
1-95.
NOTE:
Set the control to OFF if there are no neon message waiting lamps or if LED message
lamps are used. See
Figure 1-68. Setting the neon voltage
1. Call a telephone with a neon message indicator and leave a message.
2. Check for ring ping (single ring pulse) each time the lamp flashes
(approximately every 3 seconds).
3. Adjust the control clockwise in small increments until the ring ping stops.
Ensure that the message lamp still lights when the adjustment is finished.
''Set ringing option for DEFINITY ONE'' on
Figure
1-68.
didmt1 KLC 053097
Issue 6
December 2001
1-135