System Initialization
Obtain a License File

Alerts/Notifications

A mismatched or missing License File generates these alarms or signals:
Major alarm (LIC-ERR and NO-LIC) generated in the Hardware Error Log
and Alarm Log (see Alarming strategy).
Warning message at SAT login (see Log in warning messages).
Lights an administered feature button (see Feature button assignments).

Checking Alarms

The following procedures are to be used to test alarming on DEFINITY ONE™ &
IP600™.
NOTE:
If testing remotely from the Technical Service Center (TSC), you must do the
rasdrop command before doing any of the alarm tests. The rasdrop
command forces a modem disconnect after 1 minute, and gives you time to
execute the alarm test commands.
After each test has been run, the Field Services Organization (FSO) technician
will have to go to the ART web site to verify each alarm has been received.
DEFINITY Alarm Test
1. Access the DEFINITY from the lac.
2. At the command line type test inads.
3. Press <Enter>.
Intuity Alarm Test
1. Access the bash from the lac.
2. At the prompt type logsend -tTST
3. Press <Enter>.
This will result in an Intuity AUDIX alarm that should retire within a half hour.