Add Circuit Packs; Install Cables; Enter Added Translations; Resolve Alarms - Avaya DEFINITY ONE Installation And Upgrades

Internet protocol communications server
Hide thumbs Also See for DEFINITY ONE:
Table of Contents

Advertisement

Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
6
Hardware Additions
Add ISDN-PRI

Add circuit packs

1. Determine the slot assignment of the circuit packs to be added.
2. Install the DS1 Interface circuit pack in the assigned carrier slot.

Install cables

Install cables from the cabinet to the MDF as required.

Enter added translations

1. Administer the forms listed under "Integrated Services Digital Network —
Primary Rate Interface" in DEFINITY Enterprise Communications Server
Release 10 Administrator's Guide (555-233-506).

Resolve alarms

1. Examine the alarm log. Resolve any alarms that may exist using
Maintenance for DEFINITY ONE Communications System Release 10
(555-233-130) or Maintenance for IP600 Internet Protocol Server Release
10 (555-600-100).

Save translations

1. Enter save translation and press
translation information in memory and write it to the translation cards.
2. Update backup cards, if necessary.
e. Create a signaling group using the ADD SIG NEXT command. If you
are using FAS signaling, use the 16th channel on your DS1 board as
the D-channel for your signaling group. If you are using NFAS
signaling, enter N in the associated signaling field. List the trunk
board location in the Trunk Board field.
f. Create a trunk group by using the ADD TRUNK NEXT command:
1. Complete the required information on the Trunk Group form
pages.
2. Enter the port locations of the trunk members on the Trunk
Group Member page.
3. Enter the correct signaling group number.
. This instructs the system to take all
Enter
Issue 6
December 2001
6-28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ip600

Table of Contents