Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
6
Hardware Additions
Add CO, FX, WATS, and PCOL
Disable Filesystem
To free up resources on the source board, you must delete the files and disable
the filesystem.
1. Type remove file board UUCSS filename and press
image files from the source board.
2. Type disable filesystem board UUCSS and press
system on the source board.
Add CO, FX, WATS, and PCOL
Requirements
Each Central Office (CO), Foreign Exchange (FX), Personal Central Office Line
(PCOL), or Wide Area Telecommunications Service (WATS) trunk connects to 1
port of either an 8-port TN747B or to 1 of several CO trunk circuit packs.
Installation
1. Determine the port assignment of the trunk from Trunk Group form.
EXAMPLE:
2. Install a TN747B or a CO Trunk circuit pack in the assigned carrier slot (if
an additional circuit pack is required).
3. Administer the forms listed under CO, FX, WATS, or PCOL Trunk Group in
DEFINITY Enterprise Communications Server Release 10 Administrator's
Guide ( 555-233-506).
NOTE:
This process is only successful if no files remain on the source board.
Port Number
Cabinet
Network)
3
Carrier
(Port
(or Compact
Modular
Cabinet)
December 2001
to remove
Enter
to disable the file
Enter
A
07
Slo
Circuit
t
Issue 6
6-18
01