Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10 555-233-109
9
Troubleshooting
Platform troubleshooting commands
Platform troubleshooting commands
For a complete list of commands, see
commands'' on page
in DEFINITY ONE Communications System, DEFINITY ONE Release 10
Maintenance (555-233-XXX) or IP600 Release 10 Maintenance (555-233-XXX) .
Modem configuration and administration
The following procedures describe how to check settings and test the external
modem:
''Configure modem'' on page 9-5
''Verify INADS modem settings'' on page 9-5
''Verify external modem option settings'' on page 9-6
''Configure External Option Modem'' on page 9-8
''Test the external modem'' on page 9-8
NOTE:
The modem (U.S. Robotics Model) is preconfigured to work correctly.
Configure modem
Verify INADS modem settings
No external modem installed
If no external modem is connected to INADS (no INADS Alarm Origination),
proceed as follows:
1. Enter display system-parameters maintenance and press
2. Verify that the Alarm Origination Activated to OSS Numbers field is set to n
and press
3. Verify that Cleared Alarm Notification and Restart Notification are set to n.
4. Test remote access port to n.
''Avaya (Lucent) access controller bash
G-1. Detailed strategic analysis of each command is found
.
ENTER
Issue 6
December 2001
9-5
.
ENTER