Honeywell Vocollect Hardware Reference Manual page 268

Table of Contents

Advertisement

Number
Text
0x141b
Communications error: Bad
socket command.
0x1420
Error: Unable to initialize bar
code port.
0x1421
Display Mode host name or IP
address bad.
0x1422
Display Mode service name or
port bad.
0x1423
Error: Unable to initialize
Debug/training COM port.
0x1425
Socket host name or IP address
bad.
0x1426
Socket service name or port
bad.
0x1427
Unable to send file via socket.
Unable to open.
0x142a
Invalid Terminal Manager
service name or port.
0x142c
Telnet session manager failed
to start.
0x142d
Telnet client process failed to
start.
0x142e
Telnet VT220 emulation
process failed to start.
0x142f
Unable to open send data file,
for telnet send.
0x1430
Error, Unable to Initialize
Printer Port.
0x1431
Unable to print label, unable to
open file.
0x1432
Printer Error, Process Message
Service Send Error.
0x1433
Comm Error, Unable to spawn
printer process.
0x1600
File Manager initialization
failed.
Solution
1. Turn the device off and then turn it back on
again.
2. Reboot the device.
3. Reload VoiceClient.
4. Reload the task.
5. Verify the task's output data records (ODRs)
and lookup tables (LUTs) have correct and
valid socket host and service information. If
you need assistance, contact Vocollect.
1. Turn the device off and then turn it back on
again.
2. Reboot the device.
3. Reload VoiceClient.
1. Turn the device off and then turn it back on
again.
2. Reboot the device.
3. Reload VoiceClient.