Honeywell E-Mon IDR Series Installation Instructions Manual
Honeywell E-Mon IDR Series Installation Instructions Manual

Honeywell E-Mon IDR Series Installation Instructions Manual

Interval data recorder

Advertisement

E-Mon Interval Data Recorder
INSTALLATION INSTRUCTIONS
62-0394-06

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell E-Mon IDR Series

  • Page 1 E-Mon Interval Data Recorder INSTALLATION INSTRUCTIONS 62-0394-06...
  • Page 2 Before installing your new Honeywell E-Mon product, please read the information on the following pages carefully. We believe that you will find the Honeywell E-Mon meters easy to install and to use for monitoring and evaluating your electrical usage. To be sure that you are 100% satisfied with your products, we provide toll-free technical and sales support Monday through Friday, 8:00 am to 7:30 pm, EST: (800) 334-3666.
  • Page 3: Table Of Contents

    E-MON INTERVAL DATA RECORDER TABLE OF CONTENTS Section 1.0 Pre-Installation Information Section 2.0 Mechanical Installation Section 3.0 Connecting Meters to the IDR Section 4.0 AC Adapter Section 5.0 IDR Display Section 6.0 Serial Communications (EZ7) Section 7.0 Ethernet Communications Section 8.0 Protocol Definitions Appendix A DIP Switch Settings...
  • Page 4 NOTE: All internal circuits are isolated from the AC line. IDR-16’s are supplied with an ID letter for each group of 8 inputs to make them compatible with Honeywell Energy™ software. The available choices are A-B, C-D, E-F, G-H, I-J, K-L, M-N, O-P, Q-R, S-T, U-V, W-X and Y-Z.
  • Page 5 E-MON INTERVAL DATA RECORDER 1.0 PRE-INSTALLATION INFORMATION (CONTINUED) The IDR is available in two configurations. 1. Modular Jacks (IDR-8 and IDR-16): Supplied with all modular jacks for use only with Honeywell E-Mon meters. MODULAR JACKS M33954 Fig. 1. Modular Jacks.
  • Page 6 2. MMU (Multiple Meter Unit) Configuration. MMU units containing Honeywell E-Mon meters and IDRs have been pre-wired by the factory prior to shipment. The meters have been connected to the IDR. The installer needs to provide 120V power for the IDR unit in the MMU.
  • Page 7 3.0 CONNECTING METERS TO THE IDR Honeywell E-Mon Meter Connections 1. Each Honeywell E-Mon meter has two modular jacks located at the top of the main circuit board. The jack on the left (RJ-45, 8-pin) is used to connect the meter to the IDR.** NEVER USE 6-PIN JACKS LABELED “PORT 0”...
  • Page 8: Ac Adapter

    Ethernet communication activity - blink LINK Yellow Ethernet connection - solid LED on NOTE: The AC adapter provides an isolated 9 VAC/300 mA power source for the IDR. Contact Honeywell E- Mon at (800) 334-3666 if another power supply is to be used. 62-0394—06...
  • Page 9: Idr Display

    When completed, press the MENU button to save the setting and exit the function. The display shows the accumulated meter readings and the load reading of each of the input channels. The input pulse value must be entered through Honeywell E-Mon Energy software. SELECT DOWN...
  • Page 10 E-MON INTERVAL DATA RECORDER 5.0 IDR DISPLAY (CONTINUED) 5.2 Normal Run Modes 1. Energy consumption (kWh) 2. Real-Time Load (kW) 62-0394—06...
  • Page 11 1. Hardwired System using the USB Communication Key. (See the hardwired system configuration diagrams in Appendix F.) The USB communications key allows you to connect IDRs to a personal computer that has Honeywell E-Mon Energy Software installed. The computer communicates with the IDRs through the USB key.
  • Page 12: Ethernet Communications

    E-MON INTERVAL DATA RECORDER 7.0 ETHERNET COMMUNICATIONS Ethernet/IP communications connections are provided through an RJ-45 connector(J8) in the lower right corner of the main board. This port can be connected directly to a network port of a PC using a CAT 5e crossover cable or to an IP router, hub, or switch using a standard CAT 5e cable.
  • Page 13 E-MON INTERVAL DATA RECORDER 8.0 IDR PROTOCOL DEFINITIONS Table 2. Modbus Customer Point Map: IDR8 and IDR16. Integer Float Integer Address Address Registers Description Units Float Units Usage Channel 1 Pulse Pulse * Pulse Value 40001 41001 Usage Channel 2 Pulse Pulse * Pulse Value 40003...
  • Page 14 E-MON INTERVAL DATA RECORDER Table 2. Modbus Customer Point Map: IDR8 and IDR16. (Continued) Integer Float Integer Address Address Registers Description Units Float Units 40089 41089 Demand Channel 13 Demand Demand * Pulse Value 40091 41091 Demand Channel 14 Demand Demand * Pulse Value 40093 41093...
  • Page 15 E-MON INTERVAL DATA RECORDER Table 4. BACnet Object Descriptors Customer: IDR8 and IDR16. Instance BACnet Object Description Units BACnet Property Analog Input Usage Channel 1 Pulse * Pulse Value Present Value Analog Input Usage Channel 2 Pulse * Pulse Value Present Value Analog Input Usage Channel 3...
  • Page 16 With an IDR16 each channel 1 through 16 represents the IDR16 meter jack inputs 1 through 16. With an IDR8 each channel 1 through 8 represents the IDR8 meter jack inputs 1 through 8. Table 6. Honeywell E-Mon LonWorks Point Map: IDR8 and IDR16. Network Variable...
  • Page 17 E-MON INTERVAL DATA RECORDER Table 6. Honeywell E-Mon LonWorks Point Map: IDR8 and IDR16. (Continued) Network Variable Function Name Block Index SNVT Type Description Units SNVT_count_f Usage Channel 14 Pulse * Pulse Value nvoUsageCh14 SNVT_count_f Usage Channel 15 Pulse * Pulse Value...
  • Page 18 E-MON INTERVAL DATA RECORDER Table 6. Honeywell E-Mon LonWorks Point Map: IDR8 and IDR16. (Continued) Network Variable Function Name Block Index SNVT Type Description Units nvoDemandCh11 SNVT_count_f Demand Channel 11 Demand * Pulse Value nvoDemandCh12 SNVT_count_f Demand Channel 12 Demand * Pulse Value...
  • Page 19 E-MON INTERVAL DATA RECORDER Table 6. Honeywell E-Mon LonWorks Point Map: IDR8 and IDR16. (Continued) Network Variable Function Name Block Index SNVT Type Description Units SNVT_obj_stat Function Block Status Function Block Status nvoStatus SNVT_obj_requ Function Block Request Function Block nviRequest...
  • Page 20 E-MON INTERVAL DATA RECORDER Appendix A - DIP Switch Settings The 10-position DIP Switch is used to configure: • RS-485 Communication protocol (pos 1) • Ethernet Communication protocol (pos 2) • RS-485 Baud rate (pos 3 & 4) • Single channel input mode for RJ45 style connector and ST (screw terminal); dual-channel only available on RJ45.
  • Page 21: Led Indicator Locations

    E-MON INTERVAL DATA RECORDER Appendix C - LED Indicator Locations INDICATOR LEDS COMMUNICATION INDICATOR LEDS FOR ETHERNET COMMUNICATIONS M34077 Fig. 10. LED Indicator Locations Appendix D - IDR Circuit Board Components BATTERY CPU RESET FOR RTC COMMUNICATION EXTERNAL PORTS POWER IN METER INPUTS M33958 Fig.
  • Page 22: System Wiring Guides

    NOTE: INTERIOR INTERCONNECTING COMMUNICATIONS ARE SUPPLIED WITH THE PRE-WIRED MMU-TYPE METERING CABINETS. NOTE: WHEN CONSTRUCTING FIELD-INSTALLED CABLES, MODULAR CABLES MUST BE MADE SO THAT THE INDIVIDUAL WIRES GO THROUGH ON THE SAME PIN NUMBER. * CONTACT HONEYWELL FOR USB-ONLY CONNECTION. M37287 62-0394—06...
  • Page 23 NOTE: INTERIOR INTERCONNECTING COMMUNICATIONS ARE SUPPLIED WITH THE PRE-WIRED MMU-TYPE METERING CABINETS. NOTE: WHEN CONSTRUCTING FIELD-INSTALLED CABLES, MODULAR CABLES MUST BE MADE SO THAT THE INDIVIDUAL WIRES GO THROUGH ON THE SAME PIN NUMBER. * CONTACT HONEYWELL FOR USB-ONLY CONNECTION. M37288 62-0394—06...
  • Page 24: Modem System Configuration Diagrams

    E-MON INTERVAL DATA RECORDER Appendix G - Modem System Configuration Diagrams UP TO 8 METERS IDR A IDR-8, USING HONEYWELL METERS: AC ADAPTER UP TO 4000 RS-232 SERIAL PORT FEET TOTAL COM1 THROUGH COM4 MAX. 15' UP TO 52 UP TO 8 METERS...
  • Page 25 E-MON INTERVAL DATA RECORDER Appendix I - Hard Wired System Configuration Diagrams (Continued) IDR-16, USING HONEYWELL METERS AC ADAPTER UP TO 16 METERS UP TO 4000 FEET TOTAL UP TO 26 CHANNEL 1 IDR-16S RS-232 UP TO 16 METERS SERIAL PORT...
  • Page 26: Idr Technical Specifications

    36 days @ 5-minute sampling intervals 72 days @ 15-minute sampling intervals Interface with: Honeywell E-Mon submeters, electric utility meters, third-party submeters, gas meters, water meters, BTU meters, and any meter equipped with a contact pulse output (using available 2-screw terminals.) Power Consumption: 2 watts maximum, 1.2 watts typical...
  • Page 27: Meter Limited Warranty

    E-MON INTERVAL DATA RECORDER Appendix K - Meter Limited Warranty Subject to the exclusions listed below, Honeywell E-Mon will either repair or replace (at its option) any product that it manufactures and which contains a defect in material or workmanship.
  • Page 28 E-MON INTERVAL DATA RECORDER By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’...

This manual is also suitable for:

E-mon idr-8E-mon idr-16

Table of Contents