0x060c
Train returned bad status to
UpdTrain.
0x060e
Unable to train words. Not
enough free flash memory.
0x0802
Speak failed to initialize
properly.
0x0804
Speech-out failed. Audio
system failure.
0x1201
Dialog power-off failed.
0x1202
Task not loaded. No task name
available.
0x1203
OperLoad failed -- TmplSend
busy.
0x1204
Operator load failed.
0x1205
Corrupted operator data.
0x1206
Noise sample failed.
0x1207
There are no operators in this
team.
0x1208
Unable to retrieve operator
files.
0x1209
Internal error loading operator.
0x120a
Task load failed.
0x120b
Self test mode set, but no script
file found.
0x120c
No task list file found. Task
unchanged.
0x120d
Software error while changing
task. Task unchanged.
0x120e
Failed to load look up table.
Task load failed.
0x1210
Failed to load terminal
emulation configuration file.
Task load failed.
0x1211
Corrupt terminal emulation
configuration file. Task load
failed.
0x1212
Corrupt task file. Task load
failed.
Solution
1. Turn the device off and then turn it back on
again.
2. Reboot the device.
3. Reload VoiceClient.
1. Check the crashdump file. For more
information, see the VoiceConsole online
help.
2. Turn the device off and then turn it back on
again.
3. Reboot the device.
4. Reload VoiceClient.