Registry Key
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Sweden Post] - Sweden Post Symbology Configuration
SwedenPostActivation
SwedenPostCodeMark
SwedenPostUDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Infomail] - Infomail Symbology Configuration
InfomailActivation
InfomailCodeMark
InfomailUDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Intelligent Mail] - Intelligent Mail Symbology Configuration
IntelligentMailActivation
IntelligentMailCodeMark
IntelligentMailUDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Codabar] - Codabar Symbology Configuration
CodabarActivation
CodabarCodeMark
CodabarCheckDigitVerification
CodabarBarCodeLengthL1
CodabarBarCodeLengthL2
CodabarBarCodeLengthL3
CodabarBarCodeLengthMode
CodabarCheckDigitTransmission
CodabarStartStopTransmission
CodabarCLSILibrarySystem
CodabarConcatenation
CodabarConcatenationMode
CodabarUDSI
Default Value
Description
0x0
Enables the Sweden Post symbology.
0x2a
A single character inserted before the barcode data to
indicate the symbology.
"P7"
User-defined symbology identifier. Range is 0-4 characters.
0x0
Enables the Infomail symbology.
0x2a
A single character inserted before the barcode data to
indicate the symbology.
"P8"
User-defined symbology identifier. Range is 0-4 characters.
0x0
Enables the Intelligent Mail symbology.
0x2a
A single character inserted before the barcode data to
indicate the symbology.
"PA"
User-defined symbology identifier. Range is 0-4 characters.
0x0
Enables the Codabar symbology.
0x44
A single character inserted before the barcode data to
indicate the symbology.
0x0
Enables calculation of the check digit.
0x6
Length value L1. Range is 0x0 to 0xFF (0 to 255).
0x0
Length value L2. Range is 0x0 to 0xFF (0 to 255).
0x0
Length value L3. Range is 0x0 to 0xFF (0 to 255).
0x0
Length verification mode, where 0 = "L1 is min length", 1
= "L1, L2, L3 are fixed lengths", and 2 = "L1 is min, L2 is
max length".
0x0
Enable transmission of the check digit.
0x0
Selects start/stop character format to transmit, where 0 =
not transmitted, 1 = "a, b, c, d", 2 = "A, B, C, D", 3 = "a, b,
c, d / t, n, *, e", and 4 = "DC1, DC2, DC3, DC4".
0x0
Enables the CLSI (Computer Library Services, Inc) library
standard for Codabar: 14 characters, no start/stop, spaces at
positions 2, 7, and 13.
0x0
Multiple label concatenation, where 0 = disabled, 1 = only
concatenated, and 2 = concatenate if possible.
0x0
Sets requirements for concatenation, where 0 = no
requirements, 1 = Second code start = first code stop, and
2 = American Blood Commission (second code start = first
code stop = 'd').
"B7"
User-defined symbology identifier. Range is 0-4 characters.