Height
Power
Cord
Operating Temperature
Storage Temperature
Charging Temperature
Humidity
* The battery charger's components will operate in ambient temperatures between 32° and 104° F (0° and 40° C) with
no adverse effects. Functional battery charging is restricted to ambient temperatures between 41° and 95° F (5° and
35° C), to limit the internal temperature of the batteries and improve charging performance.
Note: Packaging varies for product shipments. Generally, packing materials are about 15% of the total
shipment weight.

SRX2 and A700 Battery Charger LED Indicators

The SRX2 battery charger and the A700 battery charger have an LED indicator light, located at the bottom right of
the charger face, that signals the status of the charger.
Solid green LED: Charger power is on
No light: Charger power is off
Solid red LED: Charger is experiencing a power fault (SRX2 only)
Note: If the charger LED indicator is red, unplug the charger power supply from the power source, and
remove all batteries. Plug the power supply into the power source again. If the LED remains red, the
charger may require repair or replacement.
Charger Port Indicators
Additionally, each battery port has two LED indicator lights that apply to the status of the resident battery.
The ring LED is a circular light that indicates the battery's charge status.
The alert LED, in the shape of an exclamation point (!), indicates that there is a battery condition requiring
attention. When this indicator is on, the battery on that charger port may not last a full shift. Check VoiceConsole
for a specific alert message.
The following chart describes the patterns for the battery port LED indicator lights.
Ring LED (Charge
Status)
Solid Green
Figure 154: Battery Port Indicators
Alert LED (Battery
Health)
Off
6.14" (15.6cm)
Input Voltage: 100-240 Vac
Input Current: 2.0 A maximum
Line Frequency: 50-60 Hz
Uses standard IEC 60320 plug
32° to 104° F (0° to 40° C)
-40° to 158° F (-40° to 70° C)
41° to 95° F (5° to 35° C)*
Functional to 5% to 90% non-condensing
SRX2 Battery Status
Battery is fully charged