Honeywell Vocollect Hardware Reference Manual page 42

Table of Contents

Advertisement

Registry Key
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 93] - Code 93 Symbology Configuration
Code93Activation
Code93CodeMark
Code93BarCodeLengthL1
Code93BarCodeLengthL2
Code93BarCodeLengthL3
Code93BarCodeLengthMode
Code93UDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 39] - Code 39 Symbology Configuration
Code39Activation
Code39Unconventional
Code39ReadingRange
Code39CodeMark
Code39CheckDigitVerification
Code39ReadingTolerance
Code39BarCodeLengthL1
Code39BarCodeLengthL2
Code39BarCodeLengthL3
Code39BarCodeLengthMode
Code39CheckDigitTransmission
Code39StartStopTransmission
Code39AcceptedStartCharacter
Code39FullASCIIConversion
Code39UDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Code 128] - Code 128 Symbology Configuration
Code128Activation
Default Value
Description
0x0
Enables the Code 93 symbology.
0x44
A single character inserted before the barcode data to
indicate the symbology.
0x1
Length value L1. Range is 0x0 to 0xFF (0 to 255).
0x0
Length value L2. Range is 0x0 to 0xFF (0 to 255).
0x0
Length value L3. Range is 0x0 to 0xFF (0 to 255).
0x0
Length verification mode, where 0 = "L1 is min length", 1
= "L1, L2, L3 are fixed lengths", and 2 = "L1 is min, L2 is
max length".
"B6"
User-defined symbology identifier. Range is 0-4 characters.
0x1
Enables the Code 39 symbology.
0x0
Allows decoding of unconventional Code 39 (large
intercharacter spacing or a large ratio between narrow and
wide elements).
0x1
Enables Vesta algorithm decoding for better read range.
0x2a
A single character inserted before the barcode data to
indicate the symbology.
0x0
Enables various check digit calculations, where 0 =
disabled, 1 = modulo 43, 2 = French CIP, 3 = Italian CPI, 4
= HIBC, and 5 = AIAG.
0x0
Tolerance for reading "hard to read" barcodes, where 0 =
high, 1 = medium, and 2 = low.
0x0
Length value L1. Range is 0x0 to 0xFF (0 to 255).
0x0
Length value L1. Range is 0x0 to 0xFF (0 to 255).
0x0
Length value L1. Range is 0x0 to 0xFF (0 to 255).
0x0
Length verification mode, where 0 = "L1 is min length", 1
= "L1, L2, L3 are fixed lengths", and 2 = "L1 is min, L2 is
max length".
0x0
Enable transmission of the check digit.
0x0
Enables transmission of start/stop characters.
0x2
Selects start character, where 1 = '$', 2 = '*', and 3 = '$' and
'*'.
0x0
Enables extended character set through the use of control
characters, where 0 = disabled and 1 = enabled (extended
spec).
"B1"
User-defined symbology identifier. Range is 0-4 characters.
0x1
Enables the standard Code 128 symbology.
| Talkman A700 | 42

Hide quick links:

Advertisement

Table of Contents
loading