O3: Copy Function; O4: Maintenance Monitors - Omron Q2V Series Technical Manual

Driving quality, 200 v class, three-phase: 0.1 to 22 kw, 200 v class, single-phase: 0.1 to 4.0 kw, 400 v class, three-phase: 0.37 to 30 kw
Table of Contents

Advertisement

11.12 o: KEYPAD

o3: COPY FUNCTION

No.
Name
(Hex.)
COPY Keypad Selection
o3-01
of Mode
(0515)
COPY Allow Selection
o3-02
(0516)
COPY Memory
o3-04
Selection
(0B3E)
COPY Items Selection
o3-05
(0BDA)
AutoBackup Selection
o3-06
(0BDE)
AutoBackup Lapse
o3-07
(0BDF)

o4: MAINTENANCE MONITORS

No.
Name
(Hex.)
Cum.Oper TimeSetting
o4-01
(050B)
Cum.Oper TimeSelect
o4-02
(050C)
Fan.Oper Setting
o4-03
(050E)
Cap.Maint.Setting
o4-05
(051D)
PreChgRly Preset
o4-07
Maintenance Cnt
(0523)
IGBT Preset
o4-09
Maintenance Cnt
(0525)
Flt.History Initialization
o4-11
(0510)
384
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the function that saves and copies drive parameters to a different drive with the
keypad.
0 : Copy Select
1 : Bck (Drive->OPE)
2 : Res (OPE->Drive)
3 : Verify (Check)
4 : Del (Clear OPE Memory)
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the copy function when o3-01 = 1 [COPY Keypad Selection of Mode = Bck
(Drive->OPE)].
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the storage location for drive parameters when you back up and restore parameters.
This parameter is only available when using an LCD keypad.
0 : Memory 1
1 : Memory 2
2 : Memory 3
3 : Memory 4
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets which parameters are backed up, restored, and referenced. This parameter is only
available when using an LCD keypad.
0 : Std
1 : Std+Solution
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the function that automatically backs up parameters. This parameter is only
available when using an LCD keypad.
0 : Disabled
1 : Enabled
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the interval at which the automatic parameter backup function saves parameters
from the drive to the keypad.
Note:
This parameter is only available when using an LCD keypad.
1 : 10 minutes
2 : 30 minutes
3 : 60 minutes
4 : 12 hours
Description
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the initial value of the cumulative drive operation time in 10-hour units.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the condition that counts the cumulative operation time.
1 : Log Power-On Time
2 : Log Run Time
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the value from which to start the cumulative drive cooling fan operation time in 10-
hour units.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the U4-05 [Capacitor Maintenance] monitor value.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM EZOLV
Sets the U4-06 [SoftChgRelay Maint] monitor value.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Sets the U4-07 [IGBT Maintenance] monitor value.
V/f
OLV
OLV/PM AOLV/PM EZOLV
OLV/PM
Resets the records of Monitors U2: FAULT and U3: FAULT HISTORY.
0 : No Reset
1 : Reset
Default
(Range)
0
(0 - 4)
0
(0, 1)
0
(0 - 3)
0
(0, 1)
1
(0, 1)
2
(1 - 4)
Default
(Range)
0 h
(0 - 9999 h)
1
(1, 2)
0 h
(0 - 9999 h)
0%
(0 - 150%)
0%
(0 - 150%)
0%
(0 - 150%)
0
(0, 1)
SIEPCYEUOQ2V01A Q2V Technical Manual
Ref.
705
705
705
705
706
706
Ref.
706
707
707
707
707
707
708

Advertisement

Table of Contents
loading

Table of Contents